When it comes to fire safety in dwellings, it’s not just alarms and extinguishers that matter. One often-overlooked feature, especially in older properties and loft conversions, is the fire escape window. Also known as egress windows, these are crucial for allowing occupants a safe alternative route out of a room when the main exit is blocked.
But what makes a window suitable for escape in the eyes of UK Building Regulations? Whether you’re a landlord, developer, or tradesperson working on a domestic property, this guide will help you understand the legal requirements and best practices around fire escape windows in England and Wales.
What Is a Fire Escape (Egress) Window?
A fire escape window is a window specifically designed and positioned to provide a secondary means of escape in the event of fire, particularly from upper floors or bedrooms with no direct access to a protected staircase.
They are typically required in new builds, loft conversions, and certain refurbishments, especially when designing for means of escape in two-storey homes without an alternative escape route.
When Are Fire Escape Windows Required?
According to Approved Document B (Fire Safety) of the Building Regulations:
-
In two-storey dwellings, all habitable rooms on the first floor (above ground level) must have either:
-
A fire escape window, or
-
Direct access to a protected stairway.
-
-
In single-storey dwellings, escape windows are generally required in habitable rooms unless there’s a door that opens directly to a hallway or outside.
-
For loft conversions, especially those adding a new storey to an existing home, egress windows may be necessary in all new habitable rooms unless a protected escape route is provided.
Keep in mind that planning departments and Building Control may apply these rules differently depending on layout, usage, or historical status of the property.
Fire Escape Window Size and Opening Requirements
To be classed as a compliant escape window in England and Wales, it must meet all of the following criteria:
Minimum Opening Dimensions:
-
Unobstructed opening area: 0.33 m² (i.e. 330,000 mm²)
-
Minimum height: 450 mm
-
Minimum width: 450 mm
Note: These are minimums; the actual opening may need to be larger to meet both size criteria simultaneously.
Opening Style:
-
The window must be side-hinged (casement style) to allow easy passage.
-
It must be fully openable without the use of a key or tool.
-
The opening should be bottom-hung or side-hung, not top-hung.
Height from Floor:
-
The bottom of the opening should be no more than 1100 mm above the floor level (measured internally).
-
This ensures it’s accessible for children, elderly, and disabled occupants in an emergency.
External Access and Obstacles
The area immediately outside the escape window is also crucial:
-
The window should open onto a safe place, typically a flat roof or external path, not into an enclosed courtyard unless properly risk assessed.
-
There should be nothing obstructing access (e.g., bars, fixed security grilles, or plant pots).
-
If the window opens above ground level, it should be within easy reach of the ground or a suitable platform (e.g. flat roof or escape stair).
Common Mistakes to Avoid
Even well-intentioned upgrades or refurbishments can compromise fire escape compliance. Here are common issues seen during property inspections:
-
Replacing side-hinged windows with top-hung styles
-
Adding restrictors that don’t disengage easily
-
Installing furniture directly under the window, blocking access
-
Using security locks that require a key
-
Reducing the opening size during window upgrades
-
Adding fixed grilles or bars for security
Each of these can render a compliant escape window ineffective, or non-compliant under Building Regulations and fire safety legislation.
Landlord Responsibilities
Under the Housing Act 2004 and the Housing Health and Safety Rating System (HHSRS), landlords must ensure that tenants have safe and effective means of escape from fire.
In HMOs (Houses in Multiple Occupation), fire escape window compliance is particularly important, and local authorities may inspect or request improvements as part of licensing or fire risk assessments.
If you’re a landlord upgrading or refurbishing a property, it’s wise to consult with Building Control or a qualified fire safety professional before replacing or removing any escape windows.
Summary Checklist
When inspecting or installing a fire escape window, ask yourself:
-
Does the opening area meet the 0.33 m² minimum, with 450 mm height and width?
-
Is it side-hinged and fully openable without a key?
-
Is the sill height under 1100 mm from the floor?
-
Is there clear external access and no obstructions inside or out?
If the answer to any of these is “no,” the window likely doesn’t meet current fire safety requirements.
Final Thoughts
Fire escape windows are a vital part of a building’s passive fire safety strategy, but only if they’re the right size, installed correctly, and kept accessible.
If you’re unsure about the compliance of existing windows in your property, or are planning a loft conversion, retrofit or window replacement, speak to your local Building Control officer or a certified fire safety advisor.